Security & Safety Systems
Fire Alarm Systems
Addressable and conventional fire alarm systems, code-compliant.
Overview
Early warning you can rely on, documented for audits.
A fire alarm system has one job: to warn people early enough to get out and to act. That depends on the right detector in the right place, a panel that pinpoints the location, and a system that is tested regularly, not just installed.
We design, install and commission conventional and addressable fire alarm systems for offices, plants, warehouses, hospitals and institutions, with documentation ready for fire and insurance audits.
Scope of work
What's included
- Detector and call-point layout design
- Addressable / conventional panel installation
- Compliance documentation for audits
- Testing, commissioning and AMC
Every fire alarm systems engagement follows our documented delivery process and is handed over with as-built documentation. It also qualifies for our annual maintenance program.
Delivered from our offices in Mumbai, Pune, Kolhapur and Ichalkaranji.
How we deliver it
- 01
Design
Detector, call-point and sounder layout drawn on your floor plans, following the National Building Code of India and the relevant Indian Standards such as IS 2189.
- 02
System selection
Conventional panels for smaller premises, and addressable panels where you need to know the exact device and location.
- 03
Installation
Fire-rated cabling in conduit, detectors, manual call points, sounders and the control panel, with battery backup.
- 04
Commissioning and handover
Every device tested and the alarm responses checked, with drawings, test records and a maintenance schedule handed over.
Buyer's checklist
What to check in any fire alarm quote
- Is the design drawn on your floor plan, zone by zone?
- Is the system addressable or conventional, and why?
- Is fire-rated cable specified?
- Does the alarm trigger door release, lift recall or ventilation shut-down where required?
- Is there a testing and maintenance contract after handover?
Industries we deliver this for
Talk to an engineer about fire alarm systems
FAQs
Fire Alarm Systems: common questions
Addressable or conventional fire alarm: which do we need?
A conventional system shows which zone is in alarm and suits smaller buildings. An addressable system identifies the exact detector, which saves crucial minutes in larger or multi-floor premises and makes maintenance easier.
How often should a fire alarm system be tested?
It should be checked regularly and serviced on a schedule, with periodic functional tests and a full inspection at least once a year. We set out the schedule at handover and can cover it under an AMC.
Can the fire alarm connect to access control and CCTV?
Yes. The panel can release access-controlled doors on alarm and trigger alerts, and cameras can be linked so the affected area is seen immediately.