End-to-end data centre and server room projects: design, power, cooling, racks, cabling, servers, storage and security, built by one team and maintained under AMC. From a single well-built rack to a full data centre fit-out.

What's included

Scope of work, in detail.

Every engagement is scoped in writing before work begins. Here's what each service covers.

Server Installation

Tower and rack server deployment, OS/hypervisor setup and migration.

  • Rack-mount installation and cable management
  • RAID, OS and hypervisor configuration
  • Migration from legacy hardware
  • Burn-in testing and handover documents
Service details

Rack Design

Racks planned for airflow, power, expansion and serviceability.

  • U-space and airflow planning
  • PDU and UPS sizing
  • Cable dressing standards and labeling
  • As-built rack elevation diagrams
Service details

Data Centre Build

Small and mid-size server room / data centre design and fit-out.

  • Room layout, cooling and power planning
  • Raised access and containment options
  • Fire suppression and environmental monitoring coordination
  • Complete as-built documentation pack
Service details

Enterprise Storage

NAS, SAN and backup appliances sized for your data growth.

  • NAS/SAN sizing and deployment
  • Backup strategy and appliance configuration
  • RAID and redundancy design
  • Capacity-growth planning
Service details

End to end

One team from the first drawing to the AMC.

Most data centre problems start where one vendor hands over to the next. We design, build, deploy, document and maintain the whole room ourselves.

01

Assess and design

Site survey, IT load study (kW per rack, today and in five years), room layout, power and cooling design, and the redundancy level your business actually needs, with costed options.

02

Build and fit-out

Racks and containment, UPS and power distribution, precision cooling, structured copper and fibre cabling, plus access control, CCTV and fire detection coordination.

03

Deploy compute and storage

Servers, storage, virtualization, core switching and firewalls installed, configured and burn-in tested, with migration from your existing hardware planned around your working hours.

04

Test and hand over

Load and failover tests, certified cabling, labeled racks and a complete as-built documentation pack: drawings, rack elevations, IP plans and configuration backups.

05

Operate and maintain

Annual maintenance contracts with committed response SLAs, preventive maintenance, environmental monitoring and capacity planning, so the room keeps running for years.

What we build

Every layer of the data centre, specified properly.

Here is what goes into a data centre or server room we deliver, layer by layer.

Power

  • Online double-conversion UPS sized for IT load plus growth
  • N+1 or 2N redundancy where uptime demands it
  • Battery runtime planned around generator start-up
  • Metered or switched rack PDUs with A and B feeds to every server
  • Earthing and electrical coordination with your contractor

Cooling

  • Precision (close-control) air conditioning
  • Hot aisle and cold aisle layout with blanking panels
  • Aisle containment for higher-density racks
  • Inlet temperatures planned within ASHRAE's recommended 18–27 °C range
  • Temperature and humidity sensors on every row

Racks and containment

  • 42U to 47U server and network racks, 600 or 800 mm wide
  • Depth and load rating matched to the servers going in
  • Vertical and horizontal cable management
  • Rack elevation drawings before anything is mounted

Structured cabling

  • Cat6A copper for server and switch connections
  • OM4 multimode and OS2 single-mode fibre backbones
  • High-density fibre panels and pre-terminated trunks
  • Every link labeled, tested and certified

Servers and virtualization

  • Rack and tower servers with redundant hot-swap power supplies
  • ECC memory, hardware RAID and enterprise drives
  • Out-of-band management (HPE iLO, Dell iDRAC, Lenovo XClarity)
  • Hypervisor setup, for example Microsoft Hyper-V or VMware vSphere
  • Migration from ageing hardware with a tested rollback plan

Storage and backup

  • NAS and SAN (iSCSI or Fibre Channel), hybrid or all-flash
  • Capacity sized for data growth, not just today
  • Snapshots plus a 3-2-1 backup strategy
  • Off-site or cloud copy for disaster recovery

Network and security

  • Redundant core and top-of-rack switching
  • 10 and 25 GbE server uplinks where the workload needs them
  • Next-generation firewalls, VLAN segmentation and secure VPN
  • Configuration backups handed over with the project

Monitoring and physical safety

  • Environmental monitoring: temperature, humidity, water leak and smoke
  • Alerts by email or SMS before a problem becomes an outage
  • Biometric or card access control and CCTV on the room
  • Coordination of fire detection and clean-agent gas suppression

Brands

Servers, storage and power from the brands you trust.

We deploy and supply hardware through authorized distribution, genuine and GST-invoiced, and stay brand-neutral: we recommend what fits your workload and budget.

BrandWhat we deploy
HPEProLiant rack and tower servers, MSA and Alletra storage, iLO management
Dell TechnologiesPowerEdge servers, PowerVault and PowerStore storage, iDRAC management
LenovoThinkSystem servers and storage, XClarity management
CiscoNexus data centre switching and Catalyst campus switching
APC by Schneider ElectricSmart-UPS and Galaxy UPS, NetShelter racks, rack PDUs, NetBotz monitoring
CommScopeSYSTIMAX copper and fibre cabling systems
FortinetFortiGate next-generation firewalls
SeagateExos enterprise hard drives
MicrosoftWindows Server and Hyper-V

Projects

Data centres we have built.

Mumbai · Enterprise client

A ₹3 crore enterprise data centre, delivered end to end.

The brief was a complete data centre for business-critical systems in Mumbai: designed, powered, cooled, cabled and secured as one system, with no room for a weak link between vendors.

Omnisys took single-point responsibility for the whole build. We designed the room layout, power and cooling, then delivered the racks and containment, UPS and power distribution, structured copper and fibre cabling, servers, storage and core networking, along with monitoring, access control and fire detection coordination.

Every system was tested before handover, and the client received a full as-built documentation pack, so the facility can be maintained, audited and expanded without guesswork.

Racks
14 × 42U server and network racks
Design IT load
~60 kW
UPS
2 × 80 kVA modular UPS, N+1
Cooling
3 precision AC units (N+1) with cold-aisle containment
Cabling
~600 certified copper and fibre links
Timeline
~12 weeks, design to handover
₹3 Cr
project value
14
42U racks
~60 kW
design IT load

Pune · Enterprise client

A ₹2.5 crore data centre in Pune, from design to handover.

In Pune, the client needed a data centre built properly the first time: right-sized power and cooling, clean cabling and enterprise compute, delivered on a firm scope instead of a patchwork of contractors.

We handled the project end to end, from site survey and design through racks, UPS and power distribution, precision cooling, structured cabling, server and storage deployment, networking and security, to final testing.

The result is a facility the client's IT team can run with confidence, backed by complete as-built documentation: drawings, rack elevations, IP plans and configuration backups.

Racks
10 × 42U server and network racks
Design IT load
~45 kW
UPS
2 × 60 kVA UPS, N+1
Cooling
3 precision AC units, N+1
Cabling
~400 certified copper and fibre links
Timeline
~10 weeks, design to handover
₹2.5 Cr
project value
10
42U racks
~45 kW
design IT load

Planning guide

The terms that decide a data centre's cost and uptime.

Plain-language explanations of what to ask for, so you can compare quotes properly.

Redundancy: N, N+1 and 2N

N means exactly enough capacity. N+1 adds one spare unit, so a single failure doesn't stop anything. 2N duplicates the whole path, so even a full system can fail or be serviced without downtime.

Uptime Institute Tiers

Tier I is basic capacity, Tier II adds redundant components, Tier III can be maintained without shutting down, and Tier IV tolerates faults. Most businesses don't need Tier IV; we help you pick the level that matches the cost of downtime.

TIA-942

The industry standard for data centre telecommunications infrastructure: room spaces, cabling topology, pathways and redundancy. A useful checklist for any serious server room.

ASHRAE thermal guidelines

ASHRAE recommends server inlet air between 18 and 27 °C. Running colder wastes power; running hotter shortens hardware life.

PUE (power usage effectiveness)

Total facility power divided by IT power. The closer to 1.0, the less energy goes into cooling and losses. Good airflow and containment are the cheapest ways to improve it.

FAQs

Data centre questions, answered

Do you build complete data centres or only server rooms?

Both. We handle everything from a single-rack upgrade to a full data centre fit-out: design, power, cooling, racks, cabling, servers, storage, networking, security and the AMC afterwards, as one accountable team.

Which server, storage and power brands do you supply?

We deploy and supply HPE, Dell Technologies and Lenovo servers and storage, Cisco switching, APC by Schneider Electric UPS, racks and PDUs, CommScope cabling, Fortinet firewalls and Seagate enterprise drives. We stay brand-neutral and recommend what fits your workload and budget.

Can you upgrade our existing server room without downtime?

In most cases, yes. We plan the migration in phases and in maintenance windows, keep the old and new systems running side by side where possible, and test a rollback plan before every cut-over.

How much redundancy does our data centre need?

It depends on what an hour of downtime costs you. Many businesses are well served by N+1 power and cooling; critical environments may justify 2N. We cost both options after the site survey so you can decide.

How long does a data centre or server room project take?

A single-rack upgrade can take days. A full room build depends on civil, electrical and cooling lead times. You get a written scope and timeline after the free site survey, before any commitment.

Do you maintain the data centre after handover?

Yes. Our annual maintenance contracts cover servers, storage, UPS, cooling coordination and networking with committed response times (4-hour, 8-hour or next-business-day), plus preventive maintenance visits.