Overview
A server room is a system, not a room with racks in it.
Power, cooling, cabling, fire safety and monitoring have to be designed together, because a weakness in any one of them takes the others down. That is the difference between a server room that runs quietly for years and one that fails on the hottest day of the summer.
We design and fit out small and mid-size server rooms and data centres, coordinating the civil, electrical and cooling work so you deal with one team from drawing to handover.
Scope of work
What's included
- Room layout, cooling and power planning
- Raised access and containment options
- Fire suppression and environmental monitoring coordination
- Complete as-built documentation pack
Every data centre build engagement follows our documented delivery process and is handed over with as-built documentation. It also qualifies for our annual maintenance program.
Delivered from our offices in Mumbai, Pune, Kolhapur and Ichalkaranji.
How we deliver it
- 01
Room and load study
We assess the space, the IT load in kilowatts today and after growth, and the level of redundancy the business needs.
- 02
Power and cooling design
UPS, power distribution and precision cooling sized together, with standby capacity so maintenance or a failure does not mean downtime.
- 03
Fit-out
Racks, containment, cable trays, structured cabling, access control and environmental sensors installed, with fire detection and suppression coordinated.
- 04
Testing and documentation
Load and failover tests before go-live, then a complete as-built pack: layouts, single-line diagrams, rack elevations and test records.
Buyer's checklist
What to check before building a server room
- Is the room away from water lines, sun-facing external walls and basements that flood?
- Is the cooling separate from the comfort air conditioning, and does it run round the clock?
- Are power and data cables routed separately, under a raised floor or on overhead trays?
- Are fire detection, suppression and environmental monitoring included?
- Is access to the room controlled and recorded?
Related services
Industries we deliver this for
Talk to an engineer about data centre build
FAQs
Data Centre Build: common questions
Do we need a raised floor?
Not always. Small server rooms often work well with overhead cable trays and in-row or wall-mounted precision cooling. Raised floors suit larger rooms where under-floor air distribution and cabling are worthwhile.
Can a normal split air conditioner cool a server room?
It can keep a very small room cool, but comfort units are not designed to run all day, every day, or to control humidity. For anything beyond a couple of racks we recommend precision cooling with a standby unit.
What does a server room or data centre cost?
It depends on the IT load, the redundancy you need and the condition of the room. Our projects range from single-rack server rooms to data centres of ₹2.5 to ₹3 crore, and we provide costed options after a site survey.
Let's design your infrastructure.
Tell us what you're building. We'll bring the survey kit.
We reply within 4 business hours.